Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Output Type: | Single |
| Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency




AS2000 series single-phase programmable AC inverter power supply | |||||
Model | Power capacity | OUTPUT Max Curren L= 120 V | OUTPUT Max Curren H= 240 V | weight( Kg) | volumeW×H×D( mm) |
AS2003 | 3KVA | 16.8A | 8.4A | 30 | 430×178×570 |
AS2005 | 5KVA | 42A | 21A | 50 | 430×520×550 |
AS2010 | 10KVA | 84A | 42A | 60 | 430×765×550 |
AS2015 | 15KVA | 126A | 63A | 80 | |
AS2020 | 20KVA | 168A | 84A | 120 | |
AS2030 | 30KVA | 252A | 126A | 250 | 800×1680×1050 |
AS2050 | 50KVA | 420A | 210A | 300 | |
AS2100 | 100KVA | 840A | 420A | 600 | 1000×2000×1050 |
AS2200 | 200KVA | 1680A | 840A | 800 | |
Capacity | 3KVA-10KVA | 10KVA-15KVA | 15KVA-200KVA | 200KVA | |||||
method of production | SPWM | ||||||||
INPUT | Phase | 1φ2W PE single-phase two-wire ground wire | 3φ4W PE three-phase four-wire ground wire | ||||||
Voltage | 220V±15% | 380V±15% | |||||||
Frequency | 47Hz ~ 63Hz | ||||||||
OUTPUT | Phase | 1φ2W PE single-phase two-wire ground wire | |||||||
Voltage | Low 0~150.0VAC / High 0~300.0VAC automatic AUTO (special voltage needs to be customized) | ||||||||
Frequency | 45~120Hz (40~500Hz optional, 10~1000Hz customized) 0.1Step | ||||||||
LED Display | Voltage Vrms, Current Arms, Frequency Fre, Power Wattage, Power Factor PF | ||||||||
Linear Regulation | 0.1% | ||||||||
Load Regulation | 1 % | ||||||||
Harmonic THD | 1.5%(Pure Resistive Load) | ||||||||
Frequency Regulation | 0.01% | ||||||||
Voltlage Resolution | 0.1V | ||||||||
Frequency Resolution | <100Hz 0.01 Hz, >100 Hz 0.1 Hz | ||||||||
Current Resolution | 0.01A | 0.1A | 1A | ||||||
Measurement accuracy | Voltage | 0.2%FS+5dgt | |||||||
Current | 0.3%FS+5dgt | ||||||||
Wattage | 0.45%FS+5dgt | ||||||||
Frequency | 0.01%FS+5dgt | ||||||||
The precision of the setting | Voltage | 0.2%FS | |||||||
Current | 0.01%FS | ||||||||
Memory group | There are 9 groups in total, each group can remember voltage and frequency values, and can be easily called | ||||||||
Programmable group | There are 30 sets in total, each group can operate voltage, frequency value, rise time, and running time | ||||||||
Overload capacity | 105% < output≤ 110% 15 seconds shutdown output; 110% < output≤ 200% 5-second shutdown output; 200% < output≤ 300% 2 seconds shutdown output; 300% < output Shut down the output immediately | ||||||||
Impact resistance | It can withstand 3 times the rated current for 2 s, and can withstand a power of no more than 0.5 times the rated power of the power supply The starting shock of the load or crest factor is not greater than 3.0 rectification load | ||||||||
Interface | RS232C [IEEE488.2 (GPIB) Optional] | ||||||||
I-LIM Set | O-Max Current | ||||||||
Protection | Over Current Over Temp Over Load Short Circuit | ||||||||
Operating Environment | 0 ~40°C (outdoor -20°C ~ 50°C needs to be customized) 20~90%RH | ||||||||
AS2000 Series Three-Phase Programmable AC Variable Frequency Power Supply | |||||
Model | Power capacity | OUTPUT Max Curren L= 120 V | OUTPUT Max Curren H= 240 V | weight( Kg) | volumeW×H×D( mm) |
AS2006S | 6KVA | 16.8A | 8.4A | 75 | 430×800×700 |
AS2010S | 10KVA | 28A | 14A | 90 | |
AS2015S | 15KVA | 42A | 21A | 120 | |
AS2020S | 20KVA | 56A | 28A | 150 | |
AS2030S | 30KVA | 84A | 42A | 200 | 8000×1680×850 |
AS2045S | 45KVA | 168A | 84A | 300 | |
AS2060S | 60KVA | 280A | 140A | 600 | 1000×2000×1050 |
AS2100S | 100KVA | 420A | 210A | 900 | |
AS2150S | 150KVA | 560A | 280A | 1200 | 1200×2000×1400 |
AS2300S | 300KVA | 840A | 420A | 1800 | |
AS2450S | 450KVA | 1400A | 700A | 3000 | 1800×2000×1600 |
AS21000S | 1000KVA | 2800A | 1400A | 4500 | 3600×2000×1600 |
Capacity | 6KVA-30KVA | 30KVA-45KVA | 45KVA-450KVA | 450KVA-1000KVA | |||||
Working mode | SPWM | ||||||||
INPUT | Phase | 1φ2W PE single-phase two-wire ground wire | 3φ4W PE three-phase four-wire ground wire | ||||||
Voltage | 220V±15% | 380V±15% | |||||||
Frequency | 47Hz ~ 63Hz | ||||||||
OUTPUT | Phase | 3φ4W PE three-phase four-wire ground wire | |||||||
Voltage | Low 0~150.0VAC / High 0~300.0VAC automatic AUTO (special voltage needs to be customized) | ||||||||
Frequency | 45~120 Hz (40~500 Hz meal bemachede, 10~1000 Hz customizede) 0. 1 Stap | ||||||||
LED Display | Vrms Arms Fre Wattage PF | ||||||||
Linear Regulation | 0.1% | ||||||||
Load Regulation | 1 % | ||||||||
Harmonic THD | 1.5%c(Purely resistive load) | ||||||||
Frequency Regulation | 0.01% | ||||||||
Voltlage Resolution | 0.1V | ||||||||
Frequency Resolution | <100Hz 0.01 Hz, >100Hz 0.1 Hz | ||||||||
Current Resolution | 0.01A | 0.1A | 1A | ||||||
Measurement Accuracy | Voltage | 0.2%FS+5dgt | |||||||
Current | 0.3%FS+5dgt | ||||||||
Wattage | 0.4%FS+5dgt | ||||||||
Frequency | 0.01%FS+5dgt | ||||||||
Setting Accuracy | Voltage | 0.2%FS | |||||||
Current | 0.01%FS | ||||||||
Memory Group | total of 9 groups, each capable of storing voltage and frequency values for easy recall. | ||||||||
Programmable Group | A total of 30 groups, each capable of storing operating voltage, frequency value, rise time, and running time. | ||||||||
Overload Capacity | When 105% < output ≤ 110%, the output will be turned off after 15 seconds; when 110% < output ≤ 200%, the output will be turned off after 5 seconds; when 200% < output ≤ 300%, the output will be turned off after 2 seconds; when output > 300%, the output will be turned off immediately. | ||||||||
Impact Resistance | It can withstand 3 times the rated current for 2 seconds continuously, and can withstand the starting impact of inductive loads with power not greater than 0.5 times the rated power of the power supply or rectifying loads with a crest factor not greater than 3.0. | ||||||||
Communication Interface | RS232C/RS485 [IEEE488.2 (GPIB) optional] | ||||||||
Limit Setting I-LIM | O-Max Current | ||||||||
Protection | Over Current Over Temp Over Load Short Circuit | ||||||||
Operating Environment | -10 ~45°C (outdoor: -20°C ~ 50°C needs to be customized) 0~90%RH | ||||||||